Low shower head pressure; DIY quick tip

If you are experiencing low pressure from your shower head it can be caused by several things. 


Remove showerhead and run water to check actual water volume and pressure. Before replacing showerhead it's a good idea to apply fresh plumbing tape (clockwise direction) to prevent any showerhead leaks.

Flow restrictor valve/ water saver. Remove washer and colored restrictor flow valve replace washer.


Calcium/Magnesium or lime scale build up.

Single Lever

A single lever shower set up, remove handle and cover to get access to valve and cartridge. 
Adjust hot 'red' screw, back off counter clockwise or/and cold 'blue' screw as needed for more pressure flow.
(Use Hex/Allan key, 2.5mm flathead screw driver, needle nose pliers).

You may need to replace cartridge, clear clogged pipes. 

You can purchase a water pressure gauge for your home to test overall water pressure coming into your household from city; 50 psi is generally good pressure. 

Use Hex/Allan key, 2.5mm flathead screw driver, needle nose pliers.

       

                    Smart Plumber & Rooters 408-247-2400


Comments

  1. Thanks for sharing this blog , I really appreciate this. If anybody looking for professional assistance for their blocked drains weather sewer drains, toilet drains, kitchen drains, bathroom drains or any other type of drains, Civic plumbing provide best high quality services of blocked drains Sydney. They are well know company for all plumbing solution in Sydney. You can contact them any time to get the best assistance.

    ReplyDelete
  2. Time and energy can both be saved with TubShroom when you need to clean the hair clogged drain TubShroom Canada & USA are clogged drains specialists to clean the sink.

    ReplyDelete

Post a Comment

Popular posts from this blog

Tackling A Toilet Clog For A Commercial Building

A clogged drain in your commercial building can be the cause of extreme inconvenience, an unpleasant mess, or even significant damage to the building or its interior. In cases where self-administered plumbing fixes at a basic level aren't enough, Smart Plumbers stands ready. Here we have Joel cabling a pulled toilet drain to make quick work of the back-up.

Our reputation has leaked out!

  Our Smartplumber Joey was dispatched to a familiar scenario where customers are too often faced with a sudden increase in their monthly water bill. In no time at all, our Smartplumber was able to quickly determine that the laundry room had sprung a leak; underneath the hot water line piping stone-tiled floor!   This was determined by using a thermal heat sensor that was used to locate the direction of the pipeline and where exactly the pipe damage was.   (This type of device reminds me of a Dr's stethoscope, where earphones and a sensor are used to detect and hear soft hissing sounds). Next, our Smartplumber Joey had to excavate a 1-foot hole beneath the stone tile directly above the heat source was and where the hissing sound was detected. Hey, presto! Sure enough, there was a corroded hairline crack in the 3/4" copper piping directly below.  Joey, then went on to patch the copper piping with a soldering copper patch. (These copper patches are proven to ...

A GOOD FLUSH BEATS A FULL HOUSE!

YOU NEED SEWER LINE REPAIR IF YOU SEE THESE SIGNS: Your toilet makes gargling noises. Drains aren't draining. Mold on walls. An increase in pests The toilet backs up when you flush.  Ever wondered why your bathroom smells of sewer gas odor? Without access to outside air the vacuum in the system might pull air from another plumbing fixture. For example, flushing the toilet could pull air from the bathroom sink removing the water from the P-Trap. So if you smell sewage out of the sink drain after flushing, this could be a sign of a larger ventilation issue. The P-Trap shaped piping is named after its shape. A small bend in the pipe to trap water creates a seal. This water seal prevents sewer gases and odors from leaking into your home via your drain. As water drains from the bathroom sink basin via the P-Trap, it draws air from the outside vent to equalize the pressure.  If the roof top vent is blocked by snow or some other debris then the trap seal could be sucked out by the dr...