Skip to main content

Camera Sewer Line Inspection

Camera inspection of sewer lines:



 Sewer Cameras are used to inspect the main line for cracks, roots, clogs, collapsed lines or the line can be off set. The sewer camera is not used to detect leaks.  The reason being is that the camera is entering through the opening of the sewer pipe.  A leak would be detected on the outside of the sewer pipe.  With the camera you can also detect bellying or bulging in the pipe.  The convenience of having a camera lets us see exactly where and what the problem is.  If there is a crack in the line over time roots will grow into the crack and into the pipe causing clogs and damage to the sewer line.  An off set can be caused by the earths movement; it causes the ground to shift and this will cause the sewer line to off set.



drawing of sewer camera in pipe



Remember to always call Smart Plumbers and Rooters to schedule a appointment to have one of our professional plumbers take care of all your plumbing needs. .

Comments

Popular posts from this blog

10 Amazing Plumbing Facts

1. In 1829 the Tremont Hotel in Boston was the U.S.' first hotel to use indoor plumbing. 2. Archeologists have uncovered a part of a water plumbing system at the Pyramid of Cheops in Egypt. In addition, evidence of indoor plumbing has been found in Egyptian palaces dating back to 2500 B.C. 3. Copper piping – a common material used today in plumbing – was also used by the Egyptians to lay their own pipes. 4. The toilet is flushed more times during the Super Bowl halftime than any other time during the year. 5. Albert Einstein is reported to have said that if he had to do it all over again, he’d become a plumber. Now that really puts the "Smart" in "Smart Plumbers"! 6. The “bathroom,” has had many different terms and names throughout human history and throughout different cultures. The Egyptians reportedly called it the “house of horror.” It was called the “necessarium” by the Romans. Tudor England referred to it as the “privy” or “house of privacy,” whi...

Low shower head pressure; DIY quick tip

If you are experiencing low pressure from your shower head it can be caused by several things.  Remove showerhead and run water to check actual water volume and pressure. Before replacing showerhead it's a good idea to apply fresh plumbing tape (clockwise direction) to prevent any showerhead leaks. Flow restrictor valve/ water saver. Remove washer and colored restrictor flow valve replace washer. Calcium/Magnesium or lime  scale build up. Single Lever A single lever shower set up, remove handle and cover to get access to valve and cartridge.  Adjust hot 'red' screw, back off counter clockwise or/and cold 'blue' screw as needed for more pressure  flow. (Use Hex/Allan key, 2.5mm flathead screw driver, needle nose pliers). You may need to replace cartridge, clear clogged pipes.  You can purchase a water pressure gauge for your home to test overall water pressure coming into your household from city; 50 psi is generally good pressure.  Use Hex/Allan key, 2.5mm ...

Gas Line Repair

Depicted is our plumber Patrick conducting a repair on a gas line leak with his helper technician. The line underneath the concrete going to the house had sprung a leak. Gas leaks, especially ones inside the residence or business, have the potential to be dangerous. Thankfully, they can be easy to detect and the reliability of plumbing professionals like those at Smart Plumbers will ensure that the repair is done safely and thoroughly.  If you suspect you have a leak somewhere, we recommend calling PG&E as the first step you take. The PG&E technician will come out, shut the gas off, and assess the situation before telling you the next step. If they instruct you to contact a plumber, that's where we come in to conduct the repairs. As always, call Smart Plumbers at (408) 247-2400 or email us at info@smartplumber.com.